How do you calculate weir flow?

How do you calculate weir flow?

Q = 3.33 B H3/2, where Q is the water flow rate in ft3/sec, B is the length of the weir (and the channel width) in ft, and H is the head over the weir in ft. Use of this equation is subject to the condition that H/P < 0.33 and H/B < 0.33.

What are the units for the weir coefficient?

The weir coefficient, since it is a function of the gravitational constant, is not dimensionless and therefore has different values depending on which unit system you are using. For example, a weir coefficient (C) of 3.00 in English Units would be 1.66 in SI units.

How do you calculate flow through AV notch weir?

V Notch Weir Equation for Notch Angle Other than 90 Degrees of Reclamation, Water Measurement Manual, should be used. That equation is: Q = 4.28 Ce Tan(θ/2)(H + k)5/2, where Q and H are as previously defined, θ is the angle of the v notch, Ce is the effective discharge coefficient, and k is a head correction factor.

How do you measure weir length?

The Length is the bottom width of the weir. The height is measured from the bottom of the weir opening to the top of the water level ponded behind the weir (not the water level right as it leaves the weir).

What is discharge coefficient of weir?

The flat-topped low weirs generally include broad-crested weir and short-crested weir. Under the same inflow condition, the discharge coefficient of short-crested weir is approximately 0.33–0.46, while that of broad-crested weir is 0.32–0.385, hence the former is stronger than the latter in terms of discharge capacity.

How do you calculate loading rate?

Loading rate – the speed at which forces impact the body, calculated by dividing the maximal vertical force by the time to the maximal vertical force (Bauer et al., 2001; Crossley et al., 1999).

How do you calculate water loading?

These are used to calculate loads in the following manner:

  1. volume/time x amount/volume x time = amount.
  2. feet3/second x mg/L x days x conversion factor = metric tons.
  3. liters/feet3 x sec/day x metric tons/mg = conversion factor.
  4. 28.32 x 86,400 x 1 x 10-9.
  5. = 0.0024468.
  6. liters/feet3 x seconds/day x metric tons/mg.

What is standard weir?

Standard Contracted Rectangular Weirs. The fully contracted rectangular weir (figure 7-1) is the most frequent standard weir used in irrigation. To be fully contracted, all overflow plate sides and ends must be located at least a distance of 2h1max (two maximum measurement heads) from the approach flow boundaries.

How is weir discharge coefficient calculated?

Weirs. where Cd is a discharge coefficient. In Equation (14.18) the discharge coefficient C d = ( 2 / 3 ) ( 2 g / 3 ) = 1.705 in metric units and, in Equation (14.19), C ′ d = ( 2 / 3 ) 2 / 3 = 0.544 in non-dimensional units.

What is the formula for discharge coefficient?

How do I calculate discharge coefficient for an orifice flow? To calculate discharge coefficient: Multiply the hydraulic head by the acceleration due to gravity. Multiply the resultant by 2 .

How is V notch measured?

The formula for the fully contracted V-notch weir is restricted to the following conditions:

  1. Head H < 1.25 ft (38 cm).
  2. Width B > 3 ft (91 cm).
  3. Height P > 1.5 ft (46 cm).
  4. Ratio b/H ≥ 2.0.
  5. Head/width ratio H/B ≤ 0.2.

How do you calculate notch?

The formula for calculating the notch frequency is, notch frequency= 1/4πRC, where π equals 3.14, R is the resistance, and C is the capacitance.

How do you calculate the flow rate of a rectangular weir?

The Equation. The Equation used to determine the flow rate of a Rectangular Contracted Weir is: Where: = Flow Rate in cfs. = Bottom width of the weir in feet. = Height of the upstream water above the weir crest in feet.

What is the Francis formula for flow through a weir?

The Francis Formula – Imperial Units. Flow through a rectangular weir can be expressed in imperial units with the Francis formula. q = 3.33 (b – 0.2 h) h3/2 (1b) where. q = flow rate (ft3/s) h = head on the weir (ft) b = width of the weir (ft) Alternative with height in inches and flow in gpm:

What does q mean in the weir equation?

Where: Q = discharge, C =weir coefficient, L = weir crest length, H = Energy head over the weir crest. But each of the three cases apply the weir equation slightly differently. Before I continue, I should discuss the difference between the weir coefficient and the discharge coefficient.

How do you measure a weir’s discharge?

Q = Discharge (flow rate). Head (h) should be measured at a distance of at least 4h upstream of the weir. It doesn’t matter how thick the weir is except where water flows over the weir through the “V.”