What is a good SHGC value?

What is a good SHGC value?

When it comes to an optimal SHGC rating, again you will want to look for a rating of 0.25 or less for efficient energy performance and lower A/C costs. Although for people that like their home on the warmer side should choose a SHGC rating between 0.35-0.60 to allow natural solar heat in.

What is Nfrc value?

The NFRC label helps you compare between energy-efficient windows, doors, and skylights by providing you with energy performance ratings in multiple categories. U-Factor measures how well a product can keep heat from escaping from the inside of a room. The lower the number, the better a product is at keeping heat in.

What is NFRC rated window?

The NFRC rating allows you to compare the energy efficiency of products from different manufacturers. Under the NFRC program, windows, doors, and skylights – otherwise known as fenestration products – are independently tested, certified, and labeled. The NFRC label does not recommend which products to buy.

What does NFRC 100 mean?

NFRC 100 is a set of procedures and guidelines for determining the U-factors* of windows and doors. NFRC 200 is similar to 100, except it is used to determine the Solar Heat Gain Coefficient (SHGC) and Visible Transmittance (VT) of windows and doors.

Is a lower SHGC value better?

The lower the SHGC, the better it will achieve this. Glass with a low SHGC is best used in areas of direct sunlight, for example to reduce the amount of heat coming through the windows in summer.

How can I increase my SHGC?

SHGC and U-factor can be reduced in the glass portion of a window assembly in a number of ways: Low-emissivity (low-e) coatings reduce the ultraviolet and infrared light that passes through the glass, limiting heat gain while preserving visible light transmission.

What is SHGC of clear glass?

Glass with a low SHGC is best used in areas of direct sunlight, for example to reduce the amount of heat coming through the windows in summer. For example, our 4mm clear float glass has an SHGC of 0.85, whilst ComfortPlus™ has an SHGC between 0.57 and 0.60 depending on the colour.

What is U-value and SHGC?

To comply with energy reports U values must be Lower than or equal to that specified in the report. SHGC. Solar Heat Gain Coefficient or SHGC is a measure of how much solar radiation passes through the window.

What is a NFRC 100 200 door?

What are NFRC 100 and NFRC 200? NFRC 100 is a set of procedures and guidelines for determining the U-factors* of windows and doors. NFRC 200 is similar to 100, except it is used to determine the Solar Heat Gain Coefficient (SHGC) and Visible Transmittance (VT) of windows and doors.

What is the SHGC of clear glass?

A value closer to 1.0 means that the window is relatively transparent to sunlight, and a value closer to 0.0 means that the window is relatively opaque. Typical windows have SHGC values of 0.5 to 0.75, but may vary from 0.2 (solar-control glazing) to 0.9 (thin, clear glass).

How do you calculate SHGC glass?

The shading coefficient is calculated by the equation SC = SHGC / 0.86. For example, for glazing with a SHGC of 0.6, we have 0.6 / 0.86 = 0.69, so the shading coefficient (SC) is 0.69.

What does NFRC stand for?

The National Fenestration Rating Council (NFRC) is a United States 501(c)3 non-profit organization which sponsors an energy efficiency certification and labeling program for windows, doors, and skylights.

What is the R-Value of glass?

So the reciprocal of your glass unit’s “U-Value of 0.29 can be determined by dividing the number 1 by 0.29 which would give us 3.4482 or roughly 3.5 and that would be the “R-Value” for your glass.

What material has the highest R-value?

Vacuum insulated panels have the highest R-value, approximately R-45 (in U.S. units) per inch; aerogel has the next highest R-value (about R-10 to R-30 per inch), followed by polyurethane (PUR) and phenolic foam insulations with R-7 per inch.

Is Thicker glass better for windows?

Thick glass is far more durable and less likely to break, naturally enhancing the structural stability of our windows, greatly enhancing sound control.

What is NFRC 100 and NFRC 200?

NFRC 100 is a set of procedures and guidelines for determining the U-factors* of windows and doors. NFRC 200 is similar to 100, except it is used to determine the Solar Heat Gain Coefficient (SHGC) and Visible Transmittance (VT) of windows and doors.

How is the SHGC and VT calculated in NFRC 200?

The NFRC 200 procedure calculates SHGC and VT for summer conditions of 75ºF (24ºC) interior temperature and 90ºF (32ºC) exterior temperature. End Result: The SHGC and VT of the product is determined. The SHGC can be used to determine heat gain through the products and the corresponding cooling energy demand.

What does the NFRC label mean?

View a list of NFRC-certified products. What does the NFRC label tell you? The NFRC label helps you compare between energy-efficient windows, doors, and skylights by providing you with energy performance ratings in multiple categories. U-Factor measures how well a product can keep heat from escaping from the inside of a room.

What is the difference between NFRC and U-factor?

The NFRC label helps you compare between energy-efficient windows, doors, and skylights by providing you with energy performance ratings in multiple categories. U-Factor measures how well a product can keep heat from escaping from the inside of a room. The lower the number, the better a product is at keeping heat in.