Can IP44 be used in Zone 1?

Can IP44 be used in Zone 1?

Spaces directly above a shower or bath are considered “Zone 1” while those within 60cm of a water source are “Zone 2”; both require a rating of at least IPX4 (so IP44 is acceptable).

Can IP44 be used in bathroom?

IP44 lighting is suitable for use in Zone 2 and Zone 3 (Outside Zones) – in other words, within 60cm from the edge of the bath and to a height of 2.25m from the floor.

What can be installed in bathroom zone 1?

Bathroom Zone 1 Zone 1 is the area above the bath or shower tray to a height of 2.25m from the floor. Any fitting used in this zone must have a minimum rating of IPx4* , which means it is protected against water spray from all directions.

What is IP44 suitable for?

IP44 And Above IP ratings of between 44 and 65 may be used for both indoor and general outdoor use. Anything lower than IP44 should only be used indoors, however. IP44 outdoor lights can withstand rain and are safe to use outdoors, however should not be exposed to pressurised water such as a jet wash.

Is IPX4 same as IP44?

A minimum rating of IPX4 (IP44) is required. In this zone, if there is likelihood of water jets being used for cleaning purposes, a minimum of IPX5 is required. Zone 2 – The area stretching to 0.6m outside the bath or shower and above the bath or shower if over 2.25m. An IP rating of at least IPX4 (IP44) is required.

What is IP44 waterproof?

protected against complete, continuous submersion in water. An IP44 rated connector is often referred to as “splash proof” and protects from objects greater than 1 millimeter in size and water spray from any direction.

Can you put an extractor fan in Zone 1?

◾Extractor fans installed within zone 1 must be at least IPX4. ◾Extractor fans installed within zone 1 must be fitted with 12v SELV motors with the SELV transformers and isolators fitted outside of zone 0, 1 & 2. ◾Zone 2 for a bathroom is the same height as zone 1 (2.25m) extended to 0.6m around the bath.

Is it illegal to have a plug socket in the bathroom UK?

Electrical sockets are permitted in bathrooms or shower rooms as long as they are located more than 3m from the edge of the bath or shower. Specially designed shaver units are an exception to this rule and can be located slightly nearer, but still no closer than 600mm from the bath or shower.

Is IP44 waterproof good?

An IP44 rating means that your product will be protected from solid particles that are over 1mm in size and from low velocity sprays of water from every direction.

Is it law to have an extractor fan in the bathroom?

While the law doesn’t state you must install an extractor fan in your bathroom, it is illegal not to have a source of ventilation inside. This will depend on the structural make-up of your home, but if there is no openable window in place, then an extractor fan must be installed.

Is an extractor fan a legal requirement bathroom UK?

In short the regulations require: UK bathrooms must be ventilated with either a window or an extractor fan. If there is only a toilet, a window alone is sufficient but in new-build bathrooms with a bath and shower, mechanical ventilation in the form of an extractor fan is required.

Why are electrical sockets ever rarely installed in bathrooms?

Bathrooms are considered to be a special location for electrical installations because they have an increased risk of electric shock for the users, due to being so close to water.

What is the code for bathroom ventilation?

Section R303. When this section is adopted by a community, it essentially says that, for venting purposes, bathrooms must have windows that open. The code reads that the window must have “aggregate glazing area…of not less than 3 square feet (0.3 m2), one-half of which must be openable.”

What is the IP rating for Zone 2 bathroom?

Zone 2 Zone 2 is an area stretching 0.6m outside the perimeter of the bath and to a height of 2.25m from the floor. In these bathroom zones an IP rating of at least IP44 is required. In addition, it is good practice to consider the area around a wash basin, within a 60cm radius of any tap, to be considered as zone 2.

What is an IP44 area?

This is the area directly above a bath and within a shower cubicle, up to 2.25M in height. Same as above, requires a minimum of IP44. This is the area outside of the bathroom and shower zone.

What are the electrical requirements for bathroom Zone 0?

Any fittings inside the bath or shower itself (Bathroom Zone 0) must be of a low voltage. A minimum of an IPX7 rating is needed in order to be protected against water immersion. Fittings in Bathroom Zone 1 directly above the bath or shower, should be installed at a height of 2.25m above the floor.

What is the minimum required IP rating for bathrooms?

This zone requires a minimum of IP68. This is the area within a bath tub or shower. Only 12V SELV (Safety Extra Low Voltage) equipment can be used. Requires a minimum of IP44. This is the area directly above a bath and within a shower cubicle, up to 2.25M in height. Same as above, requires a minimum of IP44.