Table of Contents
What is Restriking voltage?
Restriking voltage is the transient voltage appearing across the breaker contacts immediately after the opening of breaker contacts. It is also called Transient Recovery Voltage.
What is the cause of restriking voltage?
Restriking voltage: At current zero, a high-frequency transient voltage appears across the contacts and is caused by the rapid distribution of energy between the magnetic and electric fields associated with the plant and transmission lines of the system. This transient voltage is known as restriking voltage (Fig.
What is the Restriking voltage Mcq?
What is restriking voltage? a. The transient voltage that appears across the circuit breaker contacts at the instant of arc extinction.

How do you calculate Restriking voltage?
For a re-striking voltage having a single frequency transient component the RRRV is obtained by dividing the maximum amplitude of the oscillation by the duration of the first half wave. Higher values of natural frequencies can be related with higher rates of rise of re-striking voltage.
What is Restriking and recovery voltage?
RestrikingVoltage : it is the transient voltage that exists during the arcing time. ( natural frequency kHz ). Recovery Voltage : it is the rms voltage after final arc extinction. ( normal frequency 50 or 60 Hz).

What is Restriking phenomenon?
Restriking Transient Voltage When the current across the contact of the circuit breaker is zero, a high-frequency transient voltage develops in the whole breaker contact and is produced by the sudden distribution of energy between the electric and magnetic field. This transient voltage is called restriking voltage.
What is rate of rise of restriking voltage?
BS 116 specify the standard for evaluating amplitude factor. Rate of Rise of Restriking Voltage (RRRV): The RRRV is defined as the slope of the steepest tangent to the restriking voltage curve. It is expressed in volts per microsecond.
What factor rate of rise of restriking voltage depends?
The rate of rise of re-striking voltage is directly proportional to the natural frequency. So, the rate of rise of re-striking voltage (RRRV) is dependent upon both the inductance and capacitance of the system.
What is Restriking voltage and arc voltage?
The voltage formed across two electrodes in an a.c. circuit at zero current and during the subsequent extinction of an arc between them, causing (if sufficiently high) the restriking of the arc; specifically that across the contacts of a circuit breaker, switch, etc., after they are separated.
What is the average rate of rise of restriking voltage up to the first peak?
The average rate of rise of re-striking voltage upto first peak is. A 50 Hz, 11 kV, 3-phase alternator with earthed neutral has reactance of 7 ohms per phase and is connected to bus-bar through a circuit breaker.
What is the average rate of rise of restriking voltage upto the first peak?
Why are the isolator used?
Isolators are used for isolating the input and output ports of a device by maintaining signal flow in only one direction. They are used in microwave circuits. A circuit breaker is used to protect a device from high current surges.
What is Restriking current?
When the current across the contact of the circuit breaker is zero, a high-frequency transient voltage develops in the whole breaker contact and is produced by the sudden distribution of energy between the electric and magnetic field. This transient voltage is called restriking voltage.
What is recovery voltage and restriking voltage?
On what factors does the rate of rising of Restriking voltage depend?
What is the average rate of rise of restriking voltage?
What is recovery and restriking voltage?
What is circuit breaker What is Restriking voltage and arc voltage?
It is the transient voltage that appears across the contacts at or near current zero during arcing period. If dielectric strength rise is greater than the rise of restriking voltage then the arc will not restrike.
What are the important characteristics of restriking voltage?
The important characteristic of restriking voltage which affects the performance of the circuit breaker is as follows – Amplitude Factor – It is defined as the ratio of the peak of transient voltage to the peak system frequency voltage.
What is restriking voltage (TRV)?
Restriking voltage is the transient voltage appearing across the breaker contacts immediately after the opening of breaker contacts. It is also called Transient Recovery Voltage (TRV). Restriking voltage is associated with high frequency which die out quickly.
What is rate of rising of restriking voltage (rrrv)?
The rate of Rising of Restriking Voltage – It is defined as the slope of the steepness tangent of the restriking voltage curve. It is expressed in kV/µs. RRRV is directly proportional to the natural frequency. The expression for the restriking voltage is expressed as
What is the difference between transient voltage and recovery voltage?
Immediately after the final current interruption, the voltage that appears across the breaker contacts (transient voltage) superimposed on the power frequency system voltage (recovery voltage). Considered a simple circuit, having a circuit breaker CB, as shown in the figure below.