Is a water fountain considered a fixture?

Is a water fountain considered a fixture?

The 2006 International Building Code requires drinking fountains in all occupancies except dwelling units and and sleeping units. This section of the code has frequently been overlooked.

What is the minimum fixture clearance for a water closet in inches )?

Water closet compartments shall be not less than 30 inches (762 mm) in width and not less than 60 inches (1524 mm) in depth for floor-mounted water closets and not less than 30 inches (762 mm) in width and 56 inches (1422 mm) in depth for wall-hung water closets.

What is the minimum weight allowed for water closet flanges of hard lead?

Floor flanges of hard lead shall weigh not less than 1 pound, 9 ounces (0.7 kg) and shall be composed of lead alloy with not less than 7.75-percent antimony by weight.

Does a urinal count as a water closet?

“Urinal” means a toilet facility maintained within a toilet room for the sole purpose of urination. “Water closet” means a toilet facility maintained within a toilet room for the purpose of both defecation and urination and which is flushed with water.

Does a high low drinking fountain count as one or two?

A high-low fountain can consist of one bowl with two spouts, but is most typically two bowls and two spouts (effectively two drinking fountains).

What is the supply water fixture of drinking fountain public?

WSFU is used to calculate water supply service systems.

Individual Fixtures Minimum Fixture Branch Pipe Size Water Supply Fixture Units WSFU
(inch) Public Installations
Drinking fountain 1/2 0.5
Hose bibbs 1/2 2.5
Laundry, 1 – 3 compartments 1/2

What is code for distance between toilet and vanity?

15″
A toilet should have some elbow room between it and another fixture or vanity. The NKBA’s recommendation is at least 18″. Codes allow a minimum distance of 15″.

What is the minimum number of water closet?

19.14. 010 Uniform Plumbing Code adopted.

TYPE OF OCCUPANCY2 WATER CLOSETS (FIXTURES PER PERSON)3 LAVATORIES (FIXTURES PER PERSON)5,6
A-1 Assembly occupancy (fixed or permanent seating) – theatres, concert halls and auditoriums Male 1: 1-100 2: 101-200 3: 201-400 Male 1: 1-200 2: 201-400 3: 401-600 4: 601-750

How many fixtures does a 3/4 water line have?

14
For our example, our 1-inch pipe can have up to 30 fixture units, our 3/4-inch can have up to 14, and our 1/2-inch can have up to 4.

Is code for water supply in buildings?

2.1

IS No. Title
2064 : 1993 Code of practice for selection, installation and maintenance of sanitary appliances (second revision)
4878 : 1986 Byelaws for construction of cinema buildings (first revision)
9668 : 1990 Code of practice for provisions and maintenance for water supplies for fire fighting

What is the code for water fountain?

Split 50/50. The low drinking fountain must have the spout located not more than 36 inches above the finished floor. The high drinking fountain must have the spout mounted 38 to 43 inches above the finished floor. (The usual request from tall people is the higher the better.)

Do drinking fountains have to be recessed?

Drinking fountains with leading edges higher than 27” must be recessed in alcoves or otherwise treated so that they do not protrude more than 4” into circulation paths. Alcoves must be sized to accommodate the clear floor space required at wheelchair accessible units.

How many GPM is a fixture?

A toilet will normally use about 2-3 gallons per minute (gpm), a shower from 1.5 to 3.0 gpm, a bathroom or kitchen faucet from 2-3 gpm, a dishwasher from 2-4 gpm, and a washing machine from 3-5 gpm. When you start running more than one fixture (sink/dishwasher/toilet/etc.)

What is code for space in front of toilet?

Most codes require at least 15 inches (measured from the center of the toilet) from any side wall or obstruction and not closer than 30 inches center to center to any other sanitary fixture. (The NKBA actually recommends 32 inches.) There should be at least 24 inches of clear space in front of a toilet or bidet.

How do you calculate water closet?

The occupant load shall be determined by dividing the superficial floor area (the area determined by deducting the area occupied by pool tables from the total floor area) by 15 sq. ft per occupant. 7. Over 300 occupants, add 1 Water Closet for each additional 200 persons.

What would be the minimum number of water closets for both sexes for an office with an occupant load of 10 persons?

shall be determined on the basis of the special needs of the occupancy. or residential occupancy shall be at least one for each 10 persons of each sex. At least one water closet shall be provided for each dwelling unit.

How many fixtures can a 1/2 water line feed?

For our example, our 1-inch pipe can have up to 30 fixture units, our 3/4-inch can have up to 14, and our 1/2-inch can have up to 4.

What is the minimum number of drinking fountains required by law?

The minimum number of required drinking fountains shall comply with Table 2902.1 and Chapter 11. Drinking fountains are not required for an occupant load of 15 or fewer. For business and mercantile occupancies with an occupant load of 15 or fewer, service sinks shall not be required.

How many drinking fountains are required under the IBC?

The minimum requirement given in IBC Section 1109.5.1 is for two drinking fountains: one for persons who use wheelchairs and one for standing persons (of course, short-statured persons and children also benefit from the height of the accessible drinking fountain).

Are service sinks and drinking fountains required in commercial buildings?

Drinking fountains are not required for an occupant load of 15 or fewer. For business and mercantile occupancies with an occupant load of 15 or fewer, service sinks shall not be required.

Are drinking fountains required to be ASME A112?

Drinking fountains shall conform to ASME A112.19.1M, ASME A112.19.2M or ASME A112.19.9M and water coolers shall conform to ARI 1010. Drinking fountains and water coolers shall conform to NSF 61, Section 9. Where water is served in restaurants, drinking fountains shall not be required.