How long does a statim take to sterilize?
8 minutes
The STATIM S-cycle cassette autoclave is the fastest benchtop steriliser available. STATIM will enable you to sterilise your handpieces in only 8 minutes, which will optimise your clinical time management and improve efficiency.
How do you calibrate a Statim 5000?
Statim Boiler Recalibration
- Turn OFF main power and remove the cover from Your Statim.
- Short together PINs W1 with a “jumper” on the main PCB board.
- Turn ON the power.
- The LCD should display CALIBRATION with: 2 digits in the upper left, 2 digits in the upper right.
- Insert The Cassette.
How often should the STATIM cassette be cleaned?
To prevent your STATIM from requiring costly repairs: Change the cassette seal every 800 to 1000 cycles, or once per year. Change the air compressor filter every 6 months. Have the water filter cleaned every 2 years by a qualified service technician.
How do you clean a Statim 5000 autoclave?
Wash the interior of the cassette with dishwashing soap or a mild detergent that does not contain chlorine. Scrub the inside with a cleaning pad designed for use with Teflon®-coated surfaces. Check the water reservoir filter every week and clean if necessary. Replace only if necessary.
How do you empty water from a Statim 5000?
Place a water container below the unit. Using the drain tube (see Section 3.5 Priming the Pump, Figure 6 of the Statim 5000 User Manual) empty the contents of the reservoir into the water container. Remove any remaining water from the reservoir with a non-linting, absorbent towel.
How often should the Statim cassette be cleaned?
How do you drain a STATIM cassette autoclave?
To do so, follow these steps:
- Place a water container below the unit.
- Using the drain tube (see Section 3.5 Priming the Pump, Figure 6 of the Statim 5000 User Manual) empty the contents of the reservoir into the water container.
- Remove any remaining water from the reservoir with a non-linting, absorbent towel.
How do you clean a Statim 5000?
Why is my Statim leaking?
If your Statim is leaking steam around the cassette, and water is pooling underneath the unit, it is time to replace the seal.
How do you clean a Statim 5000 Autoclave?
How do I clean my Statim autoclave?
Use dishwashing soap or a mild detergent that does not contain chlorine. Scrub the inside of the cassette with a cleaning pad designed for use with Teflon™ coated surfaces. After scouring, rinse thoroughly with water to remove all traces of the detergent.
How do you drain a Statim cassette autoclave?
How do you empty water from a STATIM 5000?
How do you clean a STATIM 5000 Autoclave?
How do you drain an autoclave?
With the chamber door OPEN, turn the multivalve clockwise from “0“ to “FILL WATER”. chamber. Once the pressure gauge reaches “ZERO”, open the chamber door and use the drain valve and drain hose to drain ALL of the water out of the water reservoir into a pail. TURN THE AUTOCLAVE OFF AND ALLOW THE CHAMBER TO COOL.
What does error code 3 mean on statim 5000 autoclave?
If your autoclave is showing an error code, like a Statim 5000 cycle fault 3 code, it’s important to consult your Statim 5000 service manual for repair instructions. For example, Statim 5000 cycle fault 3 code means the device cassette has failed to pressurize and reach a temperature of 110C within a timeout period.
How do I maintain my statimcassette autoclave?
8 Maintaining your STATIM 8.6 Replacing the Cassette Seal To ensure optimum performance of your STATIMcassette autoclave, change the cassette seal every 500 cycles or every six months, whichever comes first. Replacement seals are available from SciCan (order number 01-100028S for STATIM2000 G4 and 01-101649S for STATIM5000 G4).
How do you load a statim 2000s cassette?
Statim 2000S Statim 5000S Hold the cassette handle in one hand and the carry handle in the other. Gently place the end of the cassette into the unit and drop the carry handle into its closed position. Plate positions for full load (10 bags) Plate positions for half load (5 bags) Loading pouched instruments
Are the statim “s” cassette autoclaves en13060 compliant?
The Statim “S” Cassette Autoclaves are fully compliant with EN13060. The details of installing, operating and servicing your Statim are all contained within this operator’s manual.