How do you use a spike adapter?

How do you use a spike adapter?

Simply Spike, Inject and Connect Any standard IV container can be spiked with the Spike Port Adaptor. Drugs can then be added safely via the side port. For administration, an administration set is connected to the end of the Spike Port Adaptor. Simply spike, inject and connect.

How do you spike a vial?

Push spike straight down into center of vial stopper, until it passes through the stopper and the clips or skirt lock securely onto vial. a. For universal clip products, gently spread clips using two hands, center spike and push straight into vial. Release clips to ensure they securely lock onto the vial closure ring.

What is a spike adapter?

Spike adapter designed to permit connection of nonvented IV spike to IV bottle that requires vent. Contains PVC and BPA.

What is a spike port?

MINITULIPE® SPIKE PORT / STANDARD The MINITULIPE® spike port from SIPPEX is a plugging and connecting device for PVC, EVA or multilayer bags that contain sterile solutions.

When spiking the IV fluid bag How do you prevent air entry into the giving set or IV line?

Fill the drip chamber one-third to one-half full by gently squeezing the chamber. Remove protective cover on the end of the tubing and keep sterile. Filling the drip chamber prevents air from entering the IV tubing.

What does it mean to spike a IV?

Spiking an intravenous (IV) bag occurs when a healthcare professional punctures an IV bag for injecting medication or for that attachment of IV tubes for patient infusion (Ref. 1). To save time, many operating rooms (ORs) will advance spike IV bags for ease of use during procedures.

What is a vial spike?

13490-13496. Vented spike for withdrawing fluids from vials or semi-rigid containers. Reduces contamination through safety snap cap. Available with green, blue & red color caps.

What are IV spikes?

So, what does “spiking the IV bag mean“? This means you will be penetrating the IV bag with the spike of the IV tubing into the spiking port of the IV bag so the contents can flow into the IV tubing and then into the patient.

What happens if you don’t prime an IV line?

Sounds obvious, but failure to adequately prime the drip chamber (which are usually marked with a fill line) will increase the likelihood of air bubbles making their way into the IV line. Especially if running at faster rates or with a shallow-fill of the drip chamber. Make sure you have actually primed the line.

Is it OK if air bubbles in IV line?

A single air bubble in a vein does not stop the heart as it is very small. However, such accidentally introduced bubbles may occasionally reach the arterial system through a patent foramen ovale and can cause random ischaemic damage, depending on their route of arterial travel.

How long can IV fluids be spiked before using?

According to CDC (Center for Disease Control) guidelines, once any IV fluid bag is spiked (an IV drip set inserted into the bag for fluid delivery), or if a needle has been inserted into the injection port for any reason, the fluids are considered stable for only 24 hours.

What does Spike mean medically?

Medical Definition of spiking : characterized by recurrent sharp rises in body temperature a spiking fever also : resulting from a sharp rise in body temperature a spiking temperature of 105°

What is a vial Adaptor?

The vial adapter is a single-use, sterile, non-invasive medical device intended for the transfer and mixing of drugs contained in vials. Puncturing the elastomeric closure of a vial is achieved by means of an integral plastic spike located in the center of the vial adapter.

Do you need to burp an IV bag?

In a variety of clinical treatment areas, efforts have been made to avoid the opportunity for VAEs to develop. Some nurses use a technique called “burping” to release any air in the IV bag prior to connection, but this is not well documented in standard training and practice.

How fast does air embolism happen from IV?

They can develop within 10 to 20 minutes or sometimes even longer after surfacing.

How much air in IV line can cause embolism?

In most cases, it will require at least 50 mL of air to result in significant risk to life, however, there are case studies in which 20 mLs or less of air rapidly infused into the patient’s circulation has resulted in a fatal air embolism.

How long can you spike a IV bag?

1, 2, 3, 4, 5, 6, 7 Newly released guidelines from the Joint Commission have mandated that intravenous (IV) solution bags be spiked no sooner than 1 hour prior to use, and discarded after that 1-hour period.

How do I use the spike adaptor?

Flip open cap on Spike Adaptor, insert tubing spike, prime tubing per facility protocol and attach Female Connector to tubing end 1 Using the Spike Adaptor, spike an IV bag up to the ridge on the spike 4 Engage Syringe Unit to Spike Adaptor and inject drug. Flush Spike Adaptor by aspirating at least 0.5 mL and re-inject 3

How do I use the equashield Spike adaptor for IV tubing?

Assembled IV bag (Refer to: Preparing an IV Bag Using an Equashield Spike Adaptor) 2. IV Tubing Set 3. Equashield Female Connector (FC-1/FC-1S) 4. Equashield Spike Adaptor (SA-1/SA-1T) 5. Empty IV Bag Procedure: 4 Remove the cap from Female Connector and engage to the Spike Adaptor attached to an empty bag 5

How do I use the equashield secondary set IV bag?

Prime the tubing per facility protocol and attach Female Connector to tubing end 1 Using the Equashield Secondary Set, spike an IV bag up to the ridge on the spike 4 Engage Syringe Unit to Spike Adaptor and inject drug.

How do I inject ll-1r into an empty IV bag?

Spike LL-1R tubing with white one-way valve into an empty IV bag 4 Withdraw approximately 15 mL of diluent into the syringe and push back into system to prime tubing; ensuring there are no air bubbles in tubing 3 Attach luer lock syringe to luer port of LL-1R