How do I test my fire alarm control panel?

How do I test my fire alarm control panel?

To Test Your Fire Alarm Using The Alarm Panel Key

  1. Insert the test key in to the bottom of the fire alarm point.
  2. At the panel, turn the key anti-clockwise.
  3. Access LED illuminates.
  4. Pres red silence key.
  5. Push the fire alarm point upwards to reset.
  6. Press the green reset key on the panel.

How do you do the weekly fire alarm test?

Fire alarm testing must be carried out every week.

  1. 1 – Do put the system “in test” (if you have fire alarm monitoring)
  2. 2 – Do check the panel has registered the correct zone.
  3. 3 – Do keep a record of weekly testing in your log book.
  4. 4 – Do carry out your weekly testing during normal working hours.

What is the difference between a SLC and a NAC?

SLCs are essentially data circuits, supporting addressable devices. NACs use an end-of-line resistor to monitor polarity and are made up of audible and visible notification devices.

How often should fire alarm panel batteries be replaced?

The National Fire Protection Association (NFPA) recommends changing the batteries in your smoke detectors every 6 months. At First Alert, we offer 10-year smoke alarms that have a built-in 10-year battery, which eliminates the need for battery replacements for the life of the detectors.

What causes faulty fire alarm?

Strong chemicals nearby. Smoke detectors are also sensitive to particles in the air that are released by strong-smelling chemicals. If you’re remodeling your home, deep cleaning, or using strong chemicals for another reason, this may be a cause of your false alarms.

What is common fault alarm?

Plant that does not require any external control tend to only be monitored for a fault condition. This monitoring is referred to as a common alarm, a fault alarm, sometimes a critical alarm or if there are two stages, a pre-alarm and a critical alarm.

What is a fenwalnet 6000 control unit?

Fire Alarm/Suppression System Control Unit DESCRIPTION The FENWALNET 6000 Fire-Alarm / Suppression Sys- tem Control Unit is a compact control unit that provides one signaling line circuit, four notification-appliance cir- cuits, two releasing circuits, and four on-board relays.

How many form-C relays does the fenwalnet 6000 have?

The FENWALNET 6000 has four Form-C relays. Three of the four relays are user-programmable for any system condition and the fourth relay is dedicated to trouble con- ditions. Each relay is rated for 1 Amp @ 28 VDC.

Does the fenwalnet 6000 integrate with analaser II?

The FENWALNET 6000 is designed to integrate seam- lessly with AnaLASER II High Sensitivity Smoke Detec- tors (HSSD) via one or more AnaLASER II Interface Modules (AIM). It also integrates with Fenwal’s Alarm- Line Cable via AlarmLine Addressable Modules and with Linear Heat-Sensing Cable (LHS) via regular monitor modules.